dc.description.abstractIntroduzione: I sistemi ibridi avanzati a circuito chiuso (AHCL), costituiti da 3 componenti interconnessi (un sensore per la lettura in continuo della glicemia, un microinfusore che infonde insulina ed un algoritmo matematico) rappresentano una possibilità di miglior controllo glicemico nei pazienti con diabete mellito di tipo 1 (DM1). L'obiettivo del nostro studio è stato determinare l’efficacia nella regolazione della glicemia del sistema ACHL Minimed 780G in pazienti con DM1 nel periodo di tempo compreso tra le due e le quattro settimane dall’avvio del dispositivo. Materiali e metodi: I pazienti con DM1 che utilizzavano terapia insulinica multiiniettiva (MDI) o microinfusore (CSII) o microinfusore associato a sensore con sospensione predittiva a basso glucosio (SAP-PLGS) o sistema ibrido a circuito chiuso (HCL) sono passati al sistema AHCL. Risultati: Sono stati inclusi nello studio retrospettivo cinquantuno pazienti adulti e pediatrici con DM 1, con età compresa tra 6 e 65 anni ed età di esordio della malattia tra 1 e 36 anni, seguiti presso il centro regionale di Diabetologia Pediatrica dell’Istituto G.Gaslini e presso la Clinica Diabetologica del Policlinico San Martino di Genova. Ad un mese dall’avvio del sistema, il time in range (TIR), compreso tra 70-180mg/dL, è aumentato dal 52.4% al 74.1%, mentre sono diminuiti l’emoglobina glicata stimata dal 7.8% al 7.1%, il tempo in iperglicemia compresa tra 180-250 mg/dL dal 25.1% al 18.0%, il tempo in iperglicemia >250mg/dL dal 16.8% al 4.7%, la glicemia media da 181.5 mg/dL a 145 mg/dL, la deviazione standard da 64.7 mg/dL a 51.6 mg/dL. Tutti questi risultati sono statisticamente significativi (p < 0.001). Non sono state riscontrate variazioni significative nel tempo in ipoglicemia. Conclusioni: i sistemi AHCL consentono ai pazienti con DM1 di ottenere rapidamente risultati ottimali nel TIR, diminuendo il tempo in iperglicemia, senza aumentare la frequenza di ipoglicemia.it_IT
dc.description.abstractIntroduction: Advanced hybrid closed-loop (AHCL) systems, consisting of 3 interconnected components (a sensor for continuous blood glucose reading, a pump that infuses insulin, and a mathematical algorithm) represent a possibility for improved glycemic control in patients with type 1 diabetes mellitus (DM1). The objective of our study was to determine the efficacy in blood glucose regulation of the ACHL Minimed 780G system in patients with DM1 during the time period between two and four weeks after device initiation. Materials and Methods: Patients with DM1 using multi-injection insulin therapy (MDI) or pump (CSII) or sensor-associated pump with predictive low-glucose suspension (SAP-PLGS) or hybrid closed-loop (HCL) system switched to the AHCL system. Results: Fifty-one adult and pediatric patients with DM 1, with age between 6 and 65 years and age of disease onset between 1 and 36 years, followed at the regional center of Pediatric Diabetology of the Istituto G.Gaslini and at the Diabetes Clinic of the Policlinico San Martino in Genoa, Italy, were included in the retrospective study. At one month from the start of the system, the time in range (TIR), between 70-180mg/dL, increased from 52.4% to 74.1%, while the estimated glycated hemoglobin decreased from 7.8% to 7. 1%, time in hyperglycemia between 180-250 mg/dL from 25.1% to 18.0%, time in hyperglycemia >250mg/dL from 16.8% to 4.7%, mean blood glucose from 181.5 mg/dL to 145 mg/dL, and standard deviation from 64.7 mg/dL to 51.6 mg/dL. All of these results were statistically significant (p < 0.001). No significant changes in time to hypoglycemia were found. Conclusions: AHCL systems allow patients with DM1 to rapidly achieve optimal results in IRR by decreasing the time in hyperglycemia without increasing the frequency of hypoglycemia.en_UK
dc.language.isoit
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.titleEfficacia di un sistema ibrido avanzato a circuito chiuso nella terapia del diabete mellito di tipo 1 in pazienti adulti e pediatrici: l'esperienza del Policlinico San Martino e dell'Istituto Giannina Gasliniit_IT
dc.title.alternativeEffectiveness of an advanced closed-circuit hybrid system in the therapy of type 1 diabetes mellitus in adult and pediatric patients: the experience of the San Martino Polyclinic and the Giannina Gaslini Instituteen_UK
dc.typeinfo:eu-repo/semantics/masterThesis
dc.publisher.nameUniversità degli studi di Genova
dc.date.academicyear2020/2021
dc.description.corsolaurea8745 - MEDICINA E CHIRURGIA
dc.description.area6 - MEDICINA E CHIRURGIA
dc.description.department100007 - DIPARTIMENTO DI MEDICINA INTERNA E SPECIALITÀ MEDICHE