Show simple item record

dc.contributor.advisorGotelli, Marco <1993>
dc.contributor.authorZargaran, Asal <1986>
dc.date.accessioned2025-12-25T14:11:45Z
dc.date.available2025-12-25T14:11:45Z
dc.date.issued2025-12-18
dc.identifier.urihttps://unire.unige.it/handle/123456789/14369
dc.description.abstractQUESTA TESI ESPLORA LE STRATEGIE PER RIDURRE IL CONSUMO ENERGETICO NEGLI EDIFICI DI PREGIO STORICO, PRESERVANDONE AL TEMPO STESSO L'INTEGRITÀ CULTURALE E STORICA. IL CASO DI STUDIO SI CONCENTRA SU HUIS DE STOVE, UN EDIFICIO BELGA DI QUATTROCENTO ANNI, COSTRUITO NEL 1612. IL RESTAURO HA COMBINATO TECNICHE DI CONSERVAZIONE TRADIZIONALI CON MODERNE MISURE DI RISTRUTTURAZIONE ENERGETICA. GLI INTERVENTI CHIAVE SIMULATI E DOCUMENTATI INCLUDONO LA RIMOZIONE DEGLI STRATI DEL TETTO DEGRADATI E L'INSTALLAZIONE DI UNO STRATO ISOLANTE DI 15 CM, LA SOSTITUZIONE DELLE TRAVI IN LEGNO DEGRADATE, L' INTEGRAZIONE DI PANNELLI FOTOVOLTAICI E IL RESTAURO DI MURATURA, FINESTRE E PORTE CON MATERIALI CONFORMI AL PATRIMONIO. IL QUADRO METODOLOGICO SOTTOLINEA L'INTEGRAZIONE DEI PRINCIPI DI SOSTENIBILITÀ ALL'INTERNO DI RIGIDE LINEE GUIDA PER LA TUTELA DEL PATRIMONIO. LE SIMULAZIONI DI PRESTAZIONE ENERGETICA DIMOSTRANO CHE L'INTERVENTO DI RISCALDAMENTO HA RIDOTTO IL FABBISOGNO DI RISCALDAMENTO COMPLESSIVO DI CIRCA IL 30%, CON L'ISOLAMENTO DEL TETTO CHE HA CONTRIBUITO PER IL 12%, LA SOSTITUZIONE DI FINESTRE E PORTE PER L'8%, L'INTEGRAZIONE DI IMPIANTI FOTOVOLTAICI PER IL 6% E IL RINFORZO DELLA MURATURA PER IL 4%. LA VALUTAZIONE ECONOMICA, BASATA SULLE FATTURE DEGLI STUDI DI ARCHITETTURA COMBINATE CON I DATI DI SIMULAZIONE, HA CONFERMATO UN PERIODO DI RIMBORSO A MEDIO TERMINE TRA 5,8 E 6,6 ANNI.it_IT
dc.description.abstractTHIS THESIS EXPLORES STRATEGIES FOR REDUCING ENERGY CONSUMPTION IN HERITAGE BUILDINGS WHILE PRESERVING THEIR CULTURAL AND HISTORICAL INTEGRITY. THE CASE STUDY FOCUSES ON HUIS DE STOVE, A FOUR-HUNDRED-YEAR- OLD BUILDING IN BELGIUM, CONSTRUCTED IN 1612. THE RESTORATION COMBINED TRADITIONAL CONSERVATION TECHNIQUES WITH MODERN ENERGY RETROFITTING MEASURES. KEY SIMULATED AND DOCUMENTED INTERVENTIONS INCLUDED THE REMOVAL OF DETERIORATED ROOF LAYERS AND THE INSTALLATION OF A 15 CM INSULATION LAYER, THE REPLACEMENT OF DECAYED TIMBER BEAMS, THE INTEGRATION OF PHOTOVOLTAIC PANELS, AND THE RESTORATION OF MASONRY, WINDOWS, AND DOORS WITH HERITAGE-COMPLIANT MATERIALS. THE METHODOLOGICAL FRAMEWORK EMPHASIZES THE INTEGRATION OF SUSTAINABILITY PRINCIPLES WITHIN STRICT HERITAGE PROTECTION GUIDELINES. ENERGY PERFORMANCE SIMULATIONS DEMONSTRATE THAT THE RETROFIT REDUCED OVERALL HEATING DEMAND BY APPROXIMATELY 30%, WITH ROOF INSULATION CONTRIBUTING 12 PERCENTAGE POINTS, WINDOW AND DOOR REPLACEMENT 8 PERCENTAGE POINTS, SOLAR PV INTEGRATION 6 PERCENTAGE POINTS, AND MASONRY REINFORCEMENT 4 PERCENTAGE POINTS. ECONOMIC EVALUATION, BASED ON ARCHITECTURAL FIRM INVOICES COMBINED WITH SIMULATION DATA, CONFIRMED A MEDIUM-TERM PAYBACK PERIOD BETWEEN 5.8 AND 6.6 YEARS.en_UK
dc.language.isoen
dc.language.isoen
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.titleRiduzione dell'energia nelle strutture storiche utilizzando energia rinnovabileit_IT
dc.title.alternativeEnergy Reduction in Historical Structure using Renewable Energyen_UK
dc.typeinfo:eu-repo/semantics/masterThesis
dc.subject.miurING-IND/09 - SISTEMI PER L'ENERGIA E L'AMBIENTE
dc.publisher.nameUniversità degli studi di Genova
dc.date.academicyear2024/2025
dc.description.corsolaurea10728 - ENGINEERING TECHNOLOGY FOR STRATEGY (AND SECURITY)
dc.description.area9 - INGEGNERIA
dc.description.department100026 - DIPARTIMENTO DI INGEGNERIA NAVALE, ELETTRICA, ELETTRONICA E DELLE TELECOMUNICAZIONI


Files in this item

This item appears in the following Collection(s)

Show simple item record